Once through, natural circulation HRSG for applications from 10,000-200,000 pph steam and 25,000-400,000 pph turbine exhaust flow, with the ability to be supplementary fired
- Supplemental firing temperatures to 1,750 °F.
- Multiple gas flow options conform to space restrictions and minimize costs
- Ideally suited for incorporation superheaters and economizers.
- Easy access to tubes for inspection, maintenance and replacement.
- Single pass design for lower gas side pressure drop.
- No Gas baffles in tube bank eliminating gas bypass.
- Single pressure design with integral steam drum
- Highly suitable for gas turbine heat recovery applications.
- Compact design results in low installation costs.
Gas Side
- Flow rates 25,000 pph to 400,000+ pph
- Flue Gas temperatures 600° F to 1600° F unfired
- Fired condition up to 1750°F
Steam Side
- Steam Flow 20,000 pph to 200,000+ pph
- Steam Pressure up to 1200+ psig
- Steam Temp. up to 1500+ °F
Drawings
|
|